This quiz has no questions yet.
← Leave quiz
AK Fire Alarm Practice Questions - Alaska Fire Alarm Installer Permit Exam
Practice mode
Question
1
of 25
QUESTION 1 / 25
Under Alaska regulation 13 AAC 50.035, what is required before an individual can install, maintain, or test fire alarm systems in Alaska?
Choose one answer below.
A
Only a general business license
✓
B
A fire system permit issued by the State Fire Marshal
✓
C
A local fire department certificate
✓
D
No permit is required
✓
QUESTION 2 / 25
What minimum NICET certification level is required for a fire alarm system installer/technician in Alaska?
Choose one answer below.
A
NICET Level I
✓
B
NICET Level II
✓
C
NICET Level III
✓
D
No NICET certification required
✓
QUESTION 3 / 25
What minimum NICET certification and experience is required for a fire alarm design professional in Alaska?
Choose one answer below.
A
NICET Level II with 2 years experience
✓
B
NICET Level III with 5 years cumulative experience in fire alarm systems
✓
C
NICET Level IV with 10 years experience
✓
D
No NICET is needed for design work
✓
QUESTION 4 / 25
What minimum experience is required for a fire alarm system supervisor in Alaska?
Choose one answer below.
A
No experience required with NICET Level II
✓
B
At least two years of cumulative experience with NICET Level II certification
✓
C
Five years with NICET Level I
✓
D
One year with any trade certification
✓
QUESTION 5 / 25
Which edition of NFPA 72 has Alaska adopted for fire alarm system requirements?
Choose one answer below.
A
NFPA 72, 2013 Edition
✓
B
NFPA 72, 2016 Edition
✓
C
NFPA 72, 2019 Edition
✓
D
NFPA 72, 2022 Edition
✓
QUESTION 6 / 25
Under 13 AAC 50.025, what is required for annual fire alarm system testing in Alaska?
Choose one answer below.
A
Testing is optional for systems under 5 years old
✓
B
Fire alarm systems must be tested and certified annually by a permitted contractor
✓
C
Only residential systems require annual testing
✓
D
Testing is required every 3 years
✓
QUESTION 7 / 25
What action can the Alaska State Fire Marshal take if a company performs fire alarm work without a permit?
Choose one answer below.
A
Issue a verbal warning only
✓
B
Order the work stopped
✓
C
Automatically issue a retroactive permit
✓
D
No enforcement action is available
✓
QUESTION 8 / 25
Per NFPA 72 as adopted in Alaska, what is the maximum spacing for spot-type smoke detectors on a smooth ceiling?
Choose one answer below.
A
20 feet
✓
B
25 feet
✓
C
30 feet
✓
D
40 feet
✓
QUESTION 9 / 25
Alaska fire alarm regulations reference 13 AAC 50.030 for fire protection systems. What does this section cover?
Choose one answer below.
A
Only sprinkler system requirements
✓
B
Requirements for installed fire protection systems including fire alarm systems
✓
C
Only portable fire extinguishers
✓
D
Building construction standards only
✓
QUESTION 10 / 25
Per NFPA 72 as adopted in Alaska, what is the minimum standby battery capacity for a fire alarm system without a generator?
Choose one answer below.
A
12 hours standby plus 5 minutes alarm
✓
B
24 hours standby plus 5 minutes alarm
✓
C
48 hours standby plus 10 minutes alarm
✓
D
72 hours standby plus 15 minutes alarm
✓
QUESTION 11 / 25
In Alaska, which edition of NFPA 72 governs testing of an existing fire alarm system that was installed under an earlier code?
Choose one answer below.
A
Only the edition in effect when the system was installed
✓
B
Only the currently adopted edition
✓
C
Either the edition in effect when installed or the currently adopted edition, as applicable
✓
D
No specific edition applies to existing systems
✓
QUESTION 12 / 25
What documentation must an applicant provide to the Alaska State Fire Marshal to obtain a fire system permit?
Choose one answer below.
A
Only a completed application form
✓
B
Supporting documentation showing minimum requirements as outlined in 13 AAC 50.035(g)
✓
C
Only proof of insurance
✓
D
A letter from a current permit holder
✓
QUESTION 13 / 25
Per NFPA 72, what is the required temporal pattern for fire alarm evacuation signals?
Choose one answer below.
A
Continuous steady tone
✓
B
Three pulses followed by a pause (temporal-three pattern)
✓
C
Two short blasts followed by one long blast
✓
D
Variable pattern based on building type
✓
QUESTION 14 / 25
Given Alaska's extreme temperatures, what special consideration applies to outdoor fire alarm equipment?
Choose one answer below.
A
No special considerations are needed
✓
B
Equipment must be rated for the expected ambient temperature range or installed in heated enclosures
✓
C
Only indoor-rated equipment may be used
✓
D
Equipment must be painted white for snow visibility
✓
QUESTION 15 / 25
Per NEC Article 760 as adopted in Alaska, what are the two main classifications of fire alarm circuits?
Choose one answer below.
A
High voltage and low voltage
✓
B
Power-limited fire alarm (PLFA) and non-power-limited fire alarm (NPLFA)
✓
C
Indoor and outdoor
✓
D
Analog and digital
✓
QUESTION 16 / 25
What type of smoke detector is recommended for areas in Alaska where slow, smoldering fires are the primary concern?
Choose one answer below.
A
Ionization detector
✓
B
Photoelectric detector
✓
C
Heat detector
✓
D
Flame detector
✓
QUESTION 17 / 25
Per NFPA 72, what is the minimum audible sound level for fire alarm notification appliances in sleeping areas?
Choose one answer below.
A
65 dBA at the pillow
✓
B
70 dBA at the pillow
✓
C
75 dBA at the pillow
✓
D
80 dBA at the pillow
✓
QUESTION 18 / 25
Per NFPA 72, what document must be completed after installing a new fire alarm system?
Choose one answer below.
A
Only the contractor's invoice
✓
B
A record of completion
✓
C
Only the building permit close-out
✓
D
A letter to the insurance company
✓
QUESTION 19 / 25
What is the function of an end-of-line resistor in a conventional fire alarm circuit?
Choose one answer below.
A
To increase signal strength
✓
B
To provide circuit supervision by maintaining a known resistance for fault detection
✓
C
To reduce voltage to safe levels
✓
D
To filter noise from the circuit
✓
QUESTION 20 / 25
Per NFPA 72, at what height must manual fire alarm boxes (pull stations) be mounted?
Choose one answer below.
A
36 to 48 inches above the floor
✓
B
42 to 54 inches above the floor
✓
C
48 to 60 inches above the floor
✓
D
54 to 72 inches above the floor
✓
QUESTION 21 / 25
In Alaska, where can applicants apply for fire system permits?
Choose one answer below.
A
Only at the State Capitol in Juneau
✓
B
Through the Alaska State Fire Marshal Office Public Portal
✓
C
Only at local fire departments
✓
D
Through the Alaska Department of Labor
✓
QUESTION 22 / 25
Per NFPA 72, what is the purpose of a fire alarm system's signaling line circuit (SLC)?
Choose one answer below.
A
To power notification appliances
✓
B
To communicate between the control panel and addressable field devices
✓
C
To connect to the telephone network
✓
D
To provide backup power
✓
QUESTION 23 / 25
What consideration is critical when designing fire alarm systems for Alaska's remote communities?
Choose one answer below.
A
Systems can have longer response times in remote areas
✓
B
Communication pathways to supervising stations must account for limited telecommunications infrastructure
✓
C
Remote areas are exempt from fire alarm requirements
✓
D
Only battery-powered systems are allowed
✓
QUESTION 24 / 25
Per NFPA 72, what is the minimum candela rating for a wall-mounted visible notification appliance in a 20x20 foot room?
Choose one answer below.
A
15 cd
✓
B
30 cd
✓
C
60 cd
✓
D
110 cd
✓
QUESTION 25 / 25
What type of fire alarm signal does a sprinkler waterflow switch generate?
Choose one answer below.
A
Supervisory signal
✓
B
Trouble signal
✓
C
Alarm signal
✓
D
Pre-alarm signal
✓
← Previous